Single core photovoltaic cable
Single core photovoltaic cable
Single core photovoltaic cable
+
  • Single core photovoltaic cable
  • Single core photovoltaic cable
  • Single core photovoltaic cable

Single core photovoltaic cable

1006211137747640320


Keyword :

Single core photovoltaic cable

Category:

Service Hotline:

  • 产品描述
  • 认证标准
  • 简要尺寸
  • Product Descriptions

    Tinned copper stranded wire

    XLPE insulation, RoHS

    XLPE jacket, RoHS

    Bending radius: 5*D

    Reference Standard

    EN50618 UL4703

    Cable Dimension

     

    Spec

    Conductor

    Insulation

    Jacket

    Construction

    Stranded O.D

    Ave. Thickness

    Min. Thickness

    O.D

    Ave. Thickness

    Min. Thickness

    O.D

    2.5mm²

    49/0.254±0.008TXR

    2.03

    0.76

    0.69

    3.7±0.05

    0.8

    0.69

    5.4±0.1

    4mm²

    56/0.285±0.008TXR

    2.46

    0.76

    0.69

    4.1±0.05

    0.8

    0.69

    5.7±0.1

    6mm²

    84/0.285±0.008TXR

    3.02

    0.76

    0.69

    4.6±0.05

    0.8

    0.69

    6.2±0.1

    10mm²

    77/0.4±0.008TXR

    4.05

    0.76

    0.69

    5.55±0.1

    0.8

    0.69

    7.1±0.1

    16mm²

    119/0.4±0.008TXR

    5.02

    0.76

    0.69

    6.6±0.1

    0.8

    0.69

    8.3±0.15

    Marking

    62930 IEC 131 1×X mm² HALOGEN FREE LOW SMOKE Jiangsu Tongling Electric Co., Ltd.
    (UL)E347221-D PV Wire 12AWG 90℃ Wet and 105℃ Dry 1000/2000V Sun Res -40℃

     

    Technical Data 

    Rated voltage

    1000V/1500V/2000V DC

    Working temperature

    -40℃~+90℃

    Max. conductor temperature

    120℃

    Short circuit temperature

    250℃ 5S

    Bending radius

    6×D

    Maximum resistance of conductor at 20℃

    2.5mm²: 8.21Ω/km  4mm²: 5.09Ω/km

    6mm²: 3.39Ω/km    10mm²: 1.95Ω/km

    16mm²: 1.29Ω/km

    Insulation resistance

    ≥580MΩ.km @ 20℃  ≥0.58MΩ.km @ 90℃

    Surface resistance of jacket

    ≥1000MΩ

    Voltage test of finished cable

    AC 6.5kV 5min,No break

    DC Voltage test of insulation

    900V,240h(85℃,3%Nacl),No break

    Tensile strength of insulation

    ≥10.3Mpa

    Elongation of insulation

    ≥150%

    Tensile strength of sheath

    ≥10.3Mpa

    elongation of sheath

    ≥150%

    Shrinkage resistant

    ≤2%

    Acid and alkali resistant

    EN60811‐404

    Ozone resistant

    EN60811‐403/EN50396‐8.1.3

    UV resistant

    EN 50289‐4‐17

    Dynamic penetrate force

    EN 50618‐Annex D

    ‐40℃,16hWinding at low temperature

    EN 60811‐504

    ‐40℃,16h)Impact at low temperature

    EN 60811‐506

    Fire performance

    IEC60332‐1‐2 , UL VW‐1

    Cland Br Content

    EN 50618

    Thermal endurance Test

    EN60216‐1,EN60216‐2,TI120

Product Introduction


Product Descriptions

Tinned copper stranded wire

XLPE insulation, RoHS

XLPE jacket, RoHS

Bending radius: 5*D

Reference Standard

EN50618 UL4703

Cable Dimension

 

Spec

Conductor

Insulation

Jacket

Construction

Stranded O.D

Ave. Thickness

Min. Thickness

O.D

Ave. Thickness

Min. Thickness

O.D

2.5mm²

49/0.254±0.008TXR

2.03

0.76

0.69

3.7±0.05

0.8

0.69

5.4±0.1

4mm²

56/0.285±0.008TXR

2.46

0.76

0.69

4.1±0.05

0.8

0.69

5.7±0.1

6mm²

84/0.285±0.008TXR

3.02

0.76

0.69

4.6±0.05

0.8

0.69

6.2±0.1

10mm²

77/0.4±0.008TXR

4.05

0.76

0.69

5.55±0.1

0.8

0.69

7.1±0.1

16mm²

119/0.4±0.008TXR

5.02

0.76

0.69

6.6±0.1

0.8

0.69

8.3±0.15

Marking

62930 IEC 131 1×X mm² HALOGEN FREE LOW SMOKE Jiangsu Tongling Electric Co., Ltd.
(UL)E347221-D PV Wire 12AWG 90℃ Wet and 105℃ Dry 1000/2000V Sun Res -40℃

 

Technical Data 

Rated voltage

1000V/1500V/2000V DC

Working temperature

-40℃~+90℃

Max. conductor temperature

120℃

Short circuit temperature

250℃ 5S

Bending radius

6×D

Maximum resistance of conductor at 20℃

2.5mm²: 8.21Ω/km  4mm²: 5.09Ω/km

6mm²: 3.39Ω/km    10mm²: 1.95Ω/km

16mm²: 1.29Ω/km

Insulation resistance

≥580MΩ.km @ 20℃  ≥0.58MΩ.km @ 90℃

Surface resistance of jacket

≥1000MΩ

Voltage test of finished cable

AC 6.5kV 5min,No break

DC Voltage test of insulation

900V,240h(85℃,3%Nacl),No break

Tensile strength of insulation

≥10.3Mpa

Elongation of insulation

≥150%

Tensile strength of sheath

≥10.3Mpa

elongation of sheath

≥150%

Shrinkage resistant

≤2%

Acid and alkali resistant

EN60811‐404

Ozone resistant

EN60811‐403/EN50396‐8.1.3

UV resistant

EN 50289‐4‐17

Dynamic penetrate force

EN 50618‐Annex D

‐40℃,16hWinding at low temperature

EN 60811‐504

‐40℃,16h)Impact at low temperature

EN 60811‐506

Fire performance

IEC60332‐1‐2 , UL VW‐1

Cland Br Content

EN 50618

Thermal endurance Test

EN60216‐1,EN60216‐2,TI120

Keyword :

Single core photovoltaic cable

Related downloads


Product Inquiry

We will contact you within one working day. Please pay attention to your email.

* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.

Inquiry Now

Contact us for best solution

Submit Now